Brand | Hioki |
---|
Analog Insulation Hitester IR4018-20
Technical Specification
Rated output voltage | 1000 V DC |
Effective maximum indicated value | 2000 MΩ |
Accuracy 1st effective measuring range | ±2 % of scale length, 2 M to 1000 MΩ |
Lower limit resistance | 1 MΩ (measurement resistance value to maintain testing voltage) |
Overload protection | 1200 V AC (10 sec.) |
AC voltage range | 0 to 600 V (50/60 Hz), ±5 % of maximum scale value accuracy, 500 kΩ or more input resistance |
Other functions | Bright LED luminous scale, Drop proof (on concrete, 1 m/1 time), Battery check, Live circuit check, Auto discharge |
Power supply | LR6 (AA) alkaline batteries ×4, Continuous use: 15 hours (no load) |
Dimensions and mass | 159 mm (6.26 in) W × 177 mm (6.97 in) H × 53 mm (2.09 in) D, 610 g (21.5 oz), (including battery, excluding test lead) |
Accessories | Test Lead L9787 ×1, LR6 (AA) alkaline batteries ×4, Instruction manual ×1, Shoulder strap ×1 |
Category: Measuring Instruments
Additional information
Reviews (0)
Be the first to review “Analog Insulation Hitester IR4018-20” Cancel reply
You must be logged in to post a review.
Related products
Lux/Light Meter FT3424
Technical Specification
Standards | DIN 5032-7: 1985 class B, JIS C 1609-1: 2006 general AA class |
Light receiving element | Silicon photo diode |
Range selection | Auto/ Manual |
Linearity | ±2% rdg. (Multiply by 1.5 for display values in excess of 3000 lx.) |
Accuracy guarantee for temperature and humidity | 21 °C to 27 °C (69.8 °F to 80.6 °F), 75% rh or less (non-condensing) |
Response time | Auto range: within 5 seconds, Manual range: within 2 seconds |
D/A output | Output level: 2 V/range f.s. (2.5 V is output when the range f.s. is exceeded.) Output accuracy: ±1% rdg. ±5 mV (at display count) |
Functions | Timer hold function, Memory function (Up to 99 measured data can be saved.), Hold, Auto power off function, Buzzer sound, Backlight, Zero adjustment |
Power supply | LR6 Alkaline battery ×2 (continuous use 300 hours), Max. rated power 500 mVA, or R6 Manganese battery ×2, or USB bus power (5 VDC) |
Dimensions and mass | 78 mm (3.07 in)W × 170 mm (6.69 in)H × 39 mm (1.54 in)D, 310 g (10.9 oz) (including the batteries) |
Accessories | Instruction Manual ×1, LR6 Alkaline battery ×2, Sensor cap (with strap) ×1, Carrying case (soft) ×1, Strap (for instrument) ×1, USB cable (0.9 m/2.95 ft) ×1, CD (USB driver, dedicated computer application software, and communications specifications) ×1 |
AC Clamp Tester 3280-10F
Technical Specification
AC Current range | 41.99 to 1000 A, 3 ranges (50 to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
DC Voltage range | 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt. |
AC Voltage range | 4.199 V to 600 V, 4 ranges (45 to 500 Hz, Average rectified), Basic accuracy: ±1.8 % rdg. ±7 dgt. |
Crest factor | N/A |
Resistance range | 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
Other functions | Continuity: Buzzer sounds at 50 Ω ±40 Ω or less, Data hold, Auto power save, Drop-proof from height of 1 meter |
Display | LCD, max. 4199 dgt., Display refresh rate: 400 ms |
Environmental protection | IP40 dustproof and waterproof |
Power supply | Coin type lithium battery (CR2032) ×1, Continuous use 120 hours |
Core jaw dia. | φ 33 mm (1.30 in) |
Dimensions and mass | 57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz) |
Accessories | CARRYING CASE 9398 ×1, TEST LEAD L9208 ×1, Coin type lithium battery (CR2032) ×1, Instruction manual ×1 |
IR Thermometer FT3700-20
Technical Specification
Measurement temperature range | -60.0 to 550.0 ˚C (-76 to 1022 ˚F), 0.1 ˚C resolution |
Accuracy | -35.0 to -0.1 ˚C (-31.0 to 31.9 ˚F) : ±10 %rdg. ±2 ˚C 0.0 to 100.0 ˚C (-32.0 to 212.0 ˚F) : ±2 ˚C 100.1 to 500.0 ˚C (212.1 to 932.0 ˚F) : ±2% rdg. Note) -60.0 to -35.1 ˚C (-76.0 to -31.1 ˚F), and over 500.1 ˚C (932.0 ˚F) : Accuracy not specified |
Response time | 1 sec (90%) |
Measurement wavelength | 8 to 14 µm |
Thermal emissivity compensation | ε=0.10 to 1.00 (0.01 step) |
Measurement field diameter | ε=0.10 to 1.00 (0.01 step) |
Sighting | Two-beam laser marker Max 1 mW (class 2), Red |
Functions | Continuous measurement mode, MAX/ MIN/ DIF (MAX - MIN)/ AVG measurement, Alarm, Backlight, Auto power-off |
Power supply | LR03 (AAA) alkaline battery ×2, 150 mVA, Continuous use of 140 hours (With laser marker, backlight and buzzer are OFF) |
Dimensions and mass | 48 mm (1.89 in) W × 172 mm (6.77 in) H × 119 mm (4.69 in) D, 256 g (9.0 oz), (including batteries) |
Accessories | Instruction manual ×1, LR03 alkaline battery ×2, Carrying case ×1 |
Pen Type Digital Multimeter 3246-60
Technical Specification
DC Voltage range | 419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. |
AC Voltage range | 4.199 V to 600 V, 4 ranges, Basic accuracy 50 - 500 Hz : ±2.3 % rdg. ±8 dgt. (Average rectified) |
Resistance range | 419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2.0 % rdg. ±4 dgt. |
Continuity buzzer | Detection level 50 Ω ±40 Ω |
Diode check | Judges the right direction only, Open terminal voltage: 3.4 V or less, Testing current: 800 µA or less |
Auto power save | Available (cancel selectable) |
Display | Digital LCD, max. 4199 digits |
Sampling rate | 2.5 times/sec |
Power supply | Coin type lithium battery (CR2032) ×1, Continuous use: 150 hours (at DC V function), 30 hours (with light turned on for 10 seconds and off for 20 seconds per cycle and in DC V function) |
Dimensions and mass | 30 mm (1.18 in)W × 182 mm (7.17 in)H × 26.5 mm (1.04 in)D, 80 g (2.8 oz) |
Accessories | Instruction manual ×1, Coin type lithium battery (CR2032) ×1 (for trial purposes only), Sleeves (Red/ Black each 1) |
Digital Tachometer FT3405
Technical Specification
Measurement method | Non-contact: Using red visible-spectrum light and reflective tape Contact: Using optional Contact Adapter |
Measurement ranges Non-contact, AVG=ON | Rotation (r/min) : (30.00 to 199.99) to (20000 to 99990), Rotation (r/s) : (0.5000 to 1.9999) to (200.0 to 1600.0), Period (ms) : (0.6000 to 1.9999) to (200.0 to 1999.9), Count : 0 to 999999 |
Measurement ranges Contact, AVG=ON | Rotation (r/min) : (15.00 to 199.99) to (2000 to 19999), Rotation (r/s) : (0.2500 to 1.9999) to (200.0 to 333.00), Period (ms) : (3.000 to 19.999) to (200.0 to 3999.9), Count : 0 to 999999 |
Measurement ranges Contact, AVG=ON | Straight-line speed (meter/min) : (1.500 to 19.999) to (200.0 to 1999.9) Straight-line speed (meter/s) : (0.0250 to 1.9999) to (20.00 to 33.30) *Using with the Peripheral ring 9212 (option) |
Accuracy | Up to 9999 counts: ±1 dgt. (AVG=ON), ±10 dgt. (AVG=OFF) 10000 counts or more: ±2 dgt. (AVG=ON), ±20 dgt. (AVG=OFF) 20000 counts or more (r/min mode only) : ±20 dgt. (AVG=ON), ±100 dgt. (AVG=OFF) Straight-line speed measurement only: ±0.5 % rdg. add to above-mentioned accuracy |
Non-contact measuring detection range | 50 mm (1.97 inch) to 500 mm (19.7 inch) |
Display refresh rate | Approx. 0.5 to 10 times/s |
Dust and water proof | IP50 (EN60529) |
Common functions | MAX/MIN display, Display hold, Average, Auto power save, Buzzer sound, Drop-proof (1 m distance onto concrete surface) |
Power supply | LR6 (AA) alkaline battery ×2, Max. rated consumption 0.5 VA |
Operating time | Continuous use 30 hrs |
AC power supply | N/A |
Dimensions and mass | 71 mm (2.80 in)W × 186 mm (7.32 in)H × 38 mm (1.50 in)D, 230 g (8.1 oz) (including batteries) |
Accessories | Instruction manual ×1, Reflective tape 9211 ×1 sheet (30 pieces/ 12 mm (0.47 in) × 12 mm (0.47 in) per piece), Carrying case C0202 ×1, LR6 (AA) alkaline battery ×2 |
Reviews
There are no reviews yet.